1.Sheath mechanical and physics performance content correlative standard request.
2.Diameter and bending radius small, lt can installation freely in narrow room.have both optical signal transmission and electricity transmission.
Geometrical Characteristics
| Cable Type | 2 |
| Cable Dimension(mm) | 7.8 |
| Cable Weight(kg/km) | 60 |
| BF Diameter(μm) | 900±50 |
Mechanical Characteristics
| Tensile Strength(N) | Long Term | 200 |
| Short Term | 600 | |
| Long Term | 300 | |
| Short Term | 1000 | |
| Crush Resistance(N/100cm) | Dynamic | 20xD(D:Cable Diameter) |
| Bending Radius(cm) | Static | 10xD(D:Cable Diameter)) |
Fiber
| Fiber Type(core/cladding dimension) | 8.3/125,50/125,62.5/125 |
Transmission Characteristics
| SMF | 50/125 | 62.5/125 | |
| 1310/1550(nm) | 850/1300(nm) | 850/1300(nm) | |
| Attenuation(dB/km) | ≤0.40/0.30 | ≤3.5/1.5 | ≤3.5/1.5 |
| Minimum Bandwidth(Mhz·km) | ≥400/400 | ≥160/500 |
Environmental Characteristics
| Operating Storage Temperature | -20℃~+60℃ |

1.Sheath mechanical and physics performance content correlative standard request.
2.Diameter and bending radius small, lt can installation freely in narrow room.have both optical signal transmission and electricity transmission.

1.It can be installed without shutting off the power.
2.Light weight and small diameter reducing the load caused by ice and wind and the load.
3.Good performance of tensile strength and temperature performance.